The importance of using a laminar laboratory hood
Types of microbiology and biochemistry laminar laboratory hoods
Vertical laminar hood
Horizontal laminar hood
Technical specifications of the laboratory hood of Zarin Steel Kosar Company
Construction features
- All stainless steel body to maintain strength and ease of cleaning
- Smooth and seamless internal surface to prevent the accumulation of pollution
- HEPA filter system with 99.99% efficiency in absorbing particles up to 0.3 microns
- Low-noise centrifugal fan with adjustable speed
- UV light for automatic sterilization after work
- Digital control panel for air speed monitoring. System performance and warning time
Custom options
- Ability to install white LED light or fluorescent lamp with adjustable intensity
- Installation of a wheeled base for easy transfer between different laboratory spaces
- Design of specific dimensions based on user space
- Possibility of connecting to a central ventilation system or vapor absorption carbon filter
Application of laminar hood in microbiology and biochemistry
In the field of microbiology, the main goal is to prevent cross-contamination between samples. By using a laminar hood, uniform air flow prevents the entry of foreign particles and microorganisms into the work environment. In the field of biochemistry, this equipment is vital for combining sensitive chemicals, enzymes and cell culture.
Zarin Steel Kausar Company provides special models for every scientific and industrial sector with special designs.
Specialized applications
- Cultivation of bacteria and fungi in controlled environments
- Preparation of cell culture media
- Performing enzymatic reactions under sterile conditions
- DNA and RNA investigation tests
- Production of pharmaceutical and biotechnological materials
Safety and construction standards
Laminar microbiology and biochemistry laboratory hood must comply with international standards in terms of design and performance. Zarin Steel Kosar complies with the following standards in the production of its products:
Laminar microbiology and biochemistry laboratory hood price in Tehran
The price of this device varies according to the type of design, size, body material and filter used.
On average, the selling price of a laminar microbiology and biochemistry laboratory hood in Tehran ranges from 45 to 120 million tomans.
More advanced models with two HEPA filters and an active carbon filter, with a digital system and automatic air flow control, are in the higher price range.
Factors influencing the price
- Steel grade (304 or 316)
- Work surface size (120, 150 or 180 cm)
- UV system and digital control
- Type of air flow (horizontal or vertical)
- Filter brand and fan power
Procedures for ordering from Zarin Steel Kosar Company
- Communication with sales consultants to determine the appropriate model based on the type of activity
- Inspection of the laboratory space and selection of dimensions
- Provision of invoice and approval of the 3D plan before production
- Manufacturing by the technical team and final testing
- Direct delivery in Tehran with full performance guarantee
After-sales service and warranty
All Zarin Steel Kausar products have 18 months valid warranty and 5 years after sales service. If there is a need to repair or replace the filter, the company's service team will be on site and perform the service. Consumable parts such as HEPA filter, centrifugal fan, and UV lamp are always available in Tehran's central warehouse to simplify the maintenance process for customers.
Benefits of buying from Zarin Steel Kosar
- Completely customized design according to the laboratory space
- Manufacturing in a specialized workshop south of Tehran and fast shipping
- Using original stainless steel sheet and standard imported filters
- Technical support by experienced experts in the field of biological equipment
- Competitive price with elimination of intermediaries
- Immediate delivery in Tehran and other industrial cities
Important points in maintaining the laminar laboratory hood
- The HEPA filter should be replaced every 6 to 12 months depending on the amount of consumption.
- Before and after each test, turn on the UV lamp for 15 minutes.
- No device should block the air outlet or inlet.
- Do not use strong or acidic detergents to clean the steel surface.
- If there is a drop in air pressure or a change in the sound level, check the system technically.
Application of laminar hood in pharmaceutical industry of Tehran
In the pharmaceutical industries of Tehran, especially the packaging lines of injectable drugs and vaccine production, environments with high biological safety are essential. Laminar microbiology and biochemistry laboratory hood plays a key role in this process.
Using this device, suspended particles and pollution are removed from the working environment and the production process is completely sterile.
Summary
In the current situation where safety and precision in laboratory environments are of great importance, it is essential to choose standard and high-quality equipment.
The sale of laminar microbiology and biochemistry laboratory hood in Tehran is carried out by Zarin Steel Kotsar Company using the latest ventilation and filter technologies. This company has been able to gain a special position among laboratory and pharmaceutical customers by using stainless steel, precise design and strong support services.
About Zarin Steel Kosar Company
Zarin Steel Kausar is a specialized manufacturer of hospital, pharmaceutical and laboratory steel equipment, including laminar hood, scrub sink, stainless steel table, medicine trolley and anti-acid shelves. All the products of this company are designed and manufactured in Tehran and comply with international quality and safety standards.


